4.4 STATUS REQUESTS
4.4.1 Command Status
{aaS1}
Returns: {aaS1bbbbccccddddeeeefffUL}
Where bbbb = Up/Converter Frequency (as above)
cccc = Down/Converter Frequency (as above)
dddd = Up/Converter Gain
eeee = Down/Converter Gain
fff = Ref. Osc. Offset
U = 0 for Non-Inverting Up/Converter, 1 for Inverting
L = 0 for Non-Inverting LNB, 1 for inverting
4.4.2 Fractional Frequency Status
{aaSF}
Returns: {aaSFxy}
Where: x = U/C Fractional Frequency (0 to 7, in 125 kHz increments)
Where: y = D/C Fractional Frequency (0 to 7, in 125 kHz increments)
4.4.3 Level Status
{aaS2}
Returns: {S2MLffppeett}
Where: M = ASCII-hex Char. MSN of bitmapped status
F indicates no alarm in group
D7 – Low = SSPB Lock Alarm
D6 – Low = SSPB Thermal Alarm
D5 Low = SSPB Amp Alarm
D4 Low = LNB Alarm
Where: L = ASCII-hex Char. LSN of bitmapped status
F indicates no alarm in group
D3 – Low = Ext. 10 MHz Ref. Osc. Alarm
D2 Low = Down/Converter Synthesizer Alarm
D1 – Low = Up/Converter Synthesizer Alarm
D0 Low = Summary Alarm
Where: ff = 2 Chars., Forward SSPB Power Detection
Range: 00 or 16 to 40 (dBm) (00 = No SSPB)
Where: pp = 2 Chars., L-Band Output Level Detection
Range: 25 to +5 (-25 to +5 dBm)
Where: rr = 2 Chars., IF Output Level Detection
Range: 25 to +5 (-25 to +5 dBm)
Where: tt = 2 Chars., on board Temperature Monitor
Range: 00 to 70 (0 to 70°C)