Integrated L-Band Up/Dn Converter LT3600 CG-1309
Page 24
4.4.4 L-Band Status
{aaS3}
Returns: {S3bbCddTReeN}
Where: bb = 2 Chars., LNB current Detection
Range: 00 to 99 ( 0 - 990 mA)
C = 1 Character, SSPB Band Control
Range: 0 = low band, 1 = high band
dd = 2 Characters, SSPB Gain
Range: –8 to –0 or ++ (dB) ++ = Full On
T = 1 Character, Up/Converter enable
Range: 0 = disable, 1 = enable
R = 1 Character, Down/Converter enable
Range: 0 = disable, 1 = enable
ee = 2 Character, SSPB current detection
Range: 00 to 30 (0 – 3.0 A)
N = 0 for SSPB Disable, 1 SSPB Enable
4.4.5 Set Cable Slope Factor
{aaFx} Where: x = numeric character
Range: 0 to 5 (dB/500 MHz)
4.4.6 Query Cable Slope Factor
{aaF}
Returns: {F = x}
Where: x = numeric character
Range: 0 to 5 (dB/500 MHz)
4.4.7 Serial Number Read
{aaID}
Returns: {aaIDyymmddxxxx}
Where : yy = last 2 digits of year
mm = month
dd = day
xxxx = 4 digit sequence number
4.4.8 Query Software Version
{aaV}
Returns: {aaVr.ii}
Where: r = Software Release number (1 – 9)
ii = Software Issue number (00 – 99)