4.3 COMMANDS
4.3.1 Set UP/Converter Frequency
{aaC1xxxxx} Where xxxx(x) = First 4 numeric data characters
Range: 0950 to 1525 (MHz) for Std. Band units
Range: 0950 to 1950 (MHz) for Extended Band units
Where (xxxx)x = Fifth character is fractional MHz as follows
0 = 0.0 MHz
1 = +0.125 MHz
2 = +0.250 MHz
3 = +0.375 MHz
4 = +0.500 MHz
5 = +0.625 MHz
6 = +0.750 MHz
7 = +0.875 MHz
Note: If only four charactors entered, 0 is assumed as fifth digit.
4.3.2 Set DOWN/Converter Frequency
{aaC2xxxxx} Where xxxx(x) = First 4 numeric data characters
Range: 0950 to 1950 (MHz) for Std and Extended Band units
Where (xxxx)x = Fifth character is fractional MHz as follows
0 = 0.0 MHz
1 = +0.125 MHz
2 = +0.250 MHz
3 = +0.375 MHz
4 = +0.500 MHz
5 = +0.625 MHz
6 = +0.750 MHz
7 = +0.875 MHz
Note: If only four charactors entered, 0 is assumed as fifth digit.
4.3.3 Set UP/Converter Gain
{aaC3xxxx} Where xxxx = 4 numeric data characters
Range: +100 to +300 (+10.0 dB to +30.0 dB)
in 0.5 dB steps
4.3.4 Set DOWN/Converter Gain
{aaC4xxxx} Where xxxx = 4 numeric data characters
Range: +250 to +450 (+25.0 dB to +45.0 dB)
in 0.5 dB steps
4.3.5 Set Internal 10 MHz Ref Oscillator Offset
{aaC5xxx} Where xxx = 3 numeric data characters
Range: 000 to 255 (0 through 10 volts)
4.3.6 Enable SSPB
{aaC6x} Where x = 0 to disable SSPB control
and x = 1 to enable SSPB control