3.2 Front Panel Alarm Settings
Menu Page
Active
Modes
Mask
(Default)
Comment
1) Starswitch
Auto
ON
STBY
Auto
Must select "Auto" Mode when Starswitch is not present.
Forces summary alarm to OFF (see Starswitch operation).
Forces summary alarm to ON (see Starswitch operation).
2)
Front Panel
Alarm Tone
Muted
On
Muted
Mutes audio tone when in alarm.
(has no effect on Summary Alarm condition).
Audio Tone will indicate an Alarm.
3)
Reference
Oscillator
N/A
Act
OK
Bad
N/A
Disable Alarm if External Reference Oscillator is not present.
Activate for External Reference Alarm (select in Edit Mode).
External Reference is detected (Active Mode)
External Reference is not detected (Active Mode).
4) LNB
N/A
Act
OK
Bad
N/A
Disable Alarm if LNB (or BDC) is not present.
Activate for LNB supply current Alarm (select in Edit Mode).
LNB supply current is within acceptable range (Active Mode)
LNB supply current is not within acceptable range (Active Mode)
Lck
N/A
Act
OK
Bad
N/A
Disable Alarm if SSPB (or BUC) is not present.
Activate for SSPB, PLL Alarm (select in Edit Mode).
SSPB, PLL is Locked (Active Mode)
SSPB, PLL is not Locked (Active Mode)
Amp
N/A
Act
OK
Bad
N/A
Disable Alarm if SSPB (or BUC) is not present.
Activate for SSPB, Amplifier Summary Alarm (select in Edit Mode).
SSPB, Amplifier Summary Alarm is OFF (Active Mode)
SSPB, Amplifier Summary Alarm is ON (Active Mode)
5) SSPB
Therm
N/A
Act
OK
Bad
N/A
Disable Alarm if SSPB (or BUC) is not present.
Activate for SSPB, Thermal Alarm (select in Edit Mode).
SSPB, Thermal Alarm is OFF (Active Mode)
SSPB, Thermal Alarm is ON (Active Mode)